Every system will need at least 1 GEM120 (ID1) meter installing to monitor the import and export of the building. Every GEM120 meter needs a power supply/voltage reference point. This could be a dedicated supply from a 6A, for example.
Every GEM120 meter will need a data connection back to the inverter’s meter communication port. Please see the previous page for the connection point.
Data connection should be a twisted pair cable, for example, Belden multi-stranded cable.
If installing multiple meters, both the data and power supply can be linked together in series.
GEM120 meters come with a split core CT that has a 2m cable.
This must not be cut down or extended.
Press and hold the GEM120CT button to change the ID settings.
GEM120CT Overview
Technical Specifications | |
Model Number | GEM-CT-45/100 |
Dimensions (HxWxD) | 119 x 17.5 x 62mm |
Working Temperature | -25°C ~ 55°C |
Protection Class | IP51 |
Display | LCD |