Common Wiring Mistakes When Installing LoRa
Overview
Incorrect wiring can cause communication failures between the inverter and the meter. This guide outlines common mistakes and how to avoid them.
Mistake | Description | Corrective Action |
|---|
Using wires from two different pairs | Mixing pairs causes signal imbalance and data loss. | Use only one twisted pair for both A and B. |
Reversing polarity (A ↔ B) | Causes no data transmission or erratic readings. | Ensure white → A (+), colour → B (–). |
Loose or incomplete terminations | Poor connections result in intermittent LoRa communication. | Check terminals are securely fastened.
|
If your LoRa device is not communicating with the inverter or meter, wiring may be the cause. This article explains how to diagnose and correct it.
Symptoms of Incorrect Wiring
-
No data displayed in monitoring portal.
-
Meter readings not updating.
-
Inverter showing “LoRa Disconnected” or “Comm Error”.
Quick Diagnostic Steps
-
Power off the inverter before inspection.
-
Check that LoRa A is connected to Meter + (10).
-
Check that LoRa B is connected to Meter – (9).
-
Confirm that white = A and colour = B throughout the run.
-
Verify that both A and B wires are from the same twisted pair.
Corrective Actions
-
Re-terminate any loose connections.
-
Replace damaged or mixed-pair cables.
-
Reset and reconnect after ensuring correct polarity.
Related Articles
Understanding LoRa Communication Between Inverter and Meter
Overview LoRa (Long Range Radio) enables wireless communication between GivEnergy inverters and energy meters, eliminating the need for hardwired connections over long distances. How It Works The LoRa module in the inverter transmits data to the LoRa ...
How to Wire the GivEnergy LoRa Data Cable
Overview This guide explains how to correctly wire the GivEnergy LoRa Data connection between the inverter and the meter for Gen3 systems. Correct wiring ensures stable data communication and prevents signal loss between devices. Wiring Instructions ...
LoRa Configuration
Note: This guide is intended for use with LoRa devices with a digital display only. Main Display in LoRa Radio Mode LoRa Mode Antenna 240VAC RS-485 L N Signal strength / Signal to noise ratio Frequency info / Spread factor Serial Port Settings Set to ...
Installing Multiple GEM120CT Meters (ID1 & ID2)
Overview Where both grid and external PV generation must be monitored, two GEM120CT meters can be installed: ID1: Grid feed measurement ID2: PV string measurement Voltage Reference Bridging Both meters share the same voltage reference for accuracy. ...
Setting the LoRa Module Channels Guides
Step One Using an RS485-USB adapter, connect a 2 core cable between the adapter and the lora module as shown in the diagram below Step Two Plug the RS485-USB Adapter into a laptop or computer and ensure that the RS485 Adpater can be seen with an Open ...