GEM630MCT
Programming the GEM630MCT Meter from ID1 to ID2
Overview Meters can be configured with IDs 1–8. ID 1 monitors the main grid; ID 2 monitors an external PV inverter or device. Steps to Change ID Press and hold ENTER until the password screen appears. Enter password 1000 using arrow buttons ▲ ▼ to ...
Connecting GEM630MCT to a GivEnergy Inverter
Overview The GEM630MCT communicates with the inverter through an RS485 Modbus link to relay metering data. RS485 Communication Wiring Connection GEM630MCT Port Inverter Port Cable Example RS485 + TXA+ (14) 485A (+) Orange / White RS485 – TXB– (13) ...
How to Install the GEM630MCT Meter
Overview Follow these steps to install and power the GEM630MCT safely and accurately. Step-by-Step Installation Isolate all power to the circuit before wiring. Mount the meter on a DIN rail inside the consumer unit or cabinet. Provide supply power (6 ...
GEM630MCT Overview
Overview The GEM630MCT is a three-phase energy meter used across GivEnergy high-voltage and commercial systems. It measures import, export, and load across all three phases using external current-transformer (CT) clamps. Required Components GEM630MCT ...