Gen 1 (A1xx-D1xx) Firmware Log
Version A187-D187 | 23-11-2024
- Add Real Time Control Registers.
- Add import limitation.
- Add BMS restart function.
- Add separate battery throughput values.
Version A193-D189 | 02-11-2024
- Add BMS 3018 support.
Version A193-D190 | 12-06-2024
- Upgrade PV current to 13.5 A.
Version A193-D191 | 09-02-2024
Software changes:
Only compatible with later Gen1 units manufactured post week 10 of 2022 (SA/SD2210+).
Not offered on older machines unless transformer compatibility is confirmed.
(Contact Support)
- New Gen1 release with faster response compared to the 4xx series.
- PV response optimisation for mismatched strings.
- Cut-off limit fix.
- Fix discharge power behaviour in Eco Mode.
- Reserve limit fix.
Add Pause Mode options:
- PauseDischarge
- PauseCharge
- PauseBoth
- NotPaused
(Cannot be scheduled; manual on/off only)
- Add G100 support for export limitation.
- Fix PV current limit for joint strings — 11 A per string as per specification.
Version A453
- Add Real Time Control Logic (RTCL), enabled via register 166.
Version D450-A451
- Resolve reporting error on cell 15.
Version D450-A450
- Remove the 2 a.m. automatic restart function.
- Fix issue preventing hardware charging after low-voltage trigger during SOC correction.
- During SOC correction, if PV is present, discharge PV does not operate while charging PV does.
- Change battery high-voltage protection from 59.5 V to 58.5 V.
Version D449-A449
- Resolve issue causing resistance on the equipment.
Version D448-A448
- Increase allowable battery charge and discharge amount.
- Optimise battery cell temperature display (negative values no longer shown as 0).
- Add remote battery reboot capability.
- Add remote recognition of battery USB disk insertion.
- Add impedance alarm.
- When inverter is not communicating with the battery, cell data now displays as 0 instead of last-known values.
- When zero output is set, PAC adjustment time is limited to within 5 seconds.
Version D447-A447
- Modify charging over-voltage value from 57.2 V to 58.5 V.
- Modify discharge under-voltage value from 45 V to 43.2 V.
Related Articles
Gen 3 Hybrid Firmware Log
Version A319-D319 | 22-12-2025 New feature: Add 3-phase meter support. Optimisation: Battery data error checking improvements. Version A318-D318 | 26-08-2025 Fix: Correct load reading when external PV metering is disabled but still connected for ...
BMS Gen 3 Firmware Log
Version BMS3-4011 | 18-12-2025 Internal resistance check optimisation. External protocol optimisations. Multiple battery pre-charge optimisation. Initial power-on SOC issues resolved. Cell over-voltage alarms adjusted to reduce false triggering. ...
Gen 2 Hybrid Firmware Log
Version A922-D922 | 02-09-2025 New feature: Add BMS AI logic self-heating functions. Enable/disable in inverter controls (requires BMS 3022+ or 4009+). Fix: BMS current value now observes correct signed integer notation. Fix: Clear hung battery data ...
BMS Gen 1 & 2 Firmware Log
Version 3022 — BMS 2.0 | 13-06-2025 Optimise issue where SOC does not drop from 100% after a minor overvoltage alarm. Optimise balance activation conditions: passive balancing is disabled when a battery cell detection fault is present. Version 3021 — ...
All-in-One (AIO) Firmware Log
Version A620-D620 | 27-09-2025 Bug fix. Add missing hardware type codes for the 3.6 kW and 5 kW versions of AIO. Version A619-D619 | 19-08-2025 Bug fix. Multiple grid loss EPS fix. Version A618-D618 | 29-04-2025 BMS upgrade optimisations. Add new ...