Version A620-D620 | 27-09-2025
- Bug fix. Add missing hardware type codes for the 3.6 kW and 5 kW versions of AIO.
Version A619-D619 | 19-08-2025
- Bug fix. Multiple grid loss EPS fix.
Version A618-D618 | 29-04-2025
- BMS upgrade optimisations.
- Add new ultra-low battery re-activation logic (ready for BAAA0013). Battery can be force charged from as low as 60 V (previously 130 V). For Service Desk use only.
Version A617-D617 | 07-04-2025
- Add Gateway-controlled import limitation for AIO with Gateway, including parallel systems.
- Increase import limitation range to 1–255 A for EU.
- Reserve and cut-off optimisations.
- Off-grid switching speed optimisations.
Version A616-D616 | 09-02-2025
To be released
- Correct reserve and cut-off register mapping.
Version A615-D615 | 24-12-2024
Not released
- Add additional real-time registers for Grid Services.
Version A614-D614 | 09-12-2024
Not released
- Add mini calibration on each full charge if required, same as LV batteries.
- Microgrid frequency shifting optimisations.
- Firmware update optimisations.
- Prevent registers cascading from Gateway to AIO in a single-AIO scenario (AC charge override bug).
- Add real-time registers allowing “Safe Registers” to be held only in RAM, with controlled EEPROM write-back.
- Import limitation default value set to 100 A and disabled; allowable range 40–200 A.
- SOC calibration mode communicated to BCU (1 = calibration, 0 = no calibration).
Version D613-A613 | 19-09-2024
- Added charging and discharging power limits in self-generation and self-consumption mode.
- Grid / off-grid retention SOC logic optimisation.
- Added AC input current limit requirement (no Gateway).
- Off-grid onboard logic optimisation.
- Optimised anti-backflow failure response time.
- Optimised battery power calculation logic.
- Battery remains active in off-grid no-load state.
- Optimised battery discharge power deviation issue.
- Pause optimisation.
- Auxiliary source shutdown delay increased from 6 seconds to 15 seconds.
- Added single-parallel status reporting to DSP.
- Added grid input current limit and enable level.
- Added battery charge and discharge power limits.
- PV power effective range changed from 50–100 W to 35–75 W.
- Fix PV energy accumulation issue when inverter is in standby.
- Load power below 50 W no longer displayed.
- Parallel SOC calibration support (requires Gateway 11).
- Added BMS software reset function.
- Expose total battery charge and discharge energy data.
- Added bypass detection error code.
Public Log – Version D613-A613 | 19-09-2024
- On / off-grid switching logic optimisation.
- Import limitation for standalone AIO (default OFF).
- Battery power calculation optimisations.
- Battery remains active when off-grid and no load present.
- Pause mode optimisation.
- Parallel mode optimisations.
- Fix PV power display below 100 W.
- Fix PV and consumption energy reporting for standalone systems.
- Load under 50 W not registered.
- Add BMS restart function.
- Add parallel SOC calibration logic (requires Gateway 11).
- Add bypass detected error code.
Version A612-D612 | 08-04-2024
- New off-grid parallel operation function.
- Add parallel CAN communication support.
- Add multi-AIO parallel energy management based on battery SOC.
- Add parallel management functionality.
Version A611-D611 | 08-04-2024
- Optimise N-PE logic.
- Optimise firmware upgrade process to reduce stuck files.
Version A610 | 15-03-2024
- Optimise BCU upgrade issue.
- Fix 10-stage charging and pause over-midnight issues.
- Fix battery pause behaviour while off-grid.
- Fix BMS / BMU communication errors.
- Fix battery “today” values always reading zero.
- Fix PV and load calculations in standalone mode.
- Fix PV under 200 W issue.
- Add BMS activate function from AC supply.
- Fix discharge beyond cut-off setting.
- New Zealand and Australia certification.
- Export limit overflow fix for large values.
Version A609-D609 | 16-10-2023
- Optimise 10-stage charge and discharge logic.
- Wi-Fi connection improvements.
- Factory aging tests (not consumer related).
Related Articles
All in One & Giv-Gateway Manual
Download Manual This manual contains the installation, configuration, and safety information from the GivEnergy All in One & Giv-Gateway User Manual for models GIV-AIO-13.5, GIV-AIO-13.5-3.6 and GIV-AIO-GW1. It is intended as a quick reference for ...
Gateway Firmware Log
Version Gateway GAAA0014 | 02-11-2025 Optimise LED display. Version Gateway GAAA0013 | 29-04-2025 Optimise G99 standard for relay reconnection to grid. 3-phase metering over-current reporting fix. Version Gateway GAAA0012 | 07-04-2025 Add import ...
Gen 2 Hybrid Firmware Log
Version A922-D922 | 02-09-2025 New feature: Add BMS AI logic self-heating functions. Enable/disable in inverter controls (requires BMS 3022+ or 4009+). Fix: BMS current value now observes correct signed integer notation. Fix: Clear hung battery data ...
All-in-One 2 (AIO2) Firmware Log
Version SI030606 | 28-11-2025 (MPPT 03, Inverter ARM/DSP 06) Fix: PV Today reset. Version SI030505 | 10-11-2025 (MPPT 03, Inverter ARM/DSP 05) Optimise master/slave battery checks; if a mismatch is detected, an upgrade is triggered. UPS Mode enabled ...
All-in-One BMU Firmware Log
Version BAAA0013 | 03-05-2025 OCV SOC improvements during charging and discharging. Ultra-low battery activation below 80 V (Service Desk use only). Requires inverter version 618 or higher. BCU can be remotely updated even while in a fault state. ...