Version A319-D319 | 22-12-2025
- New feature: Add 3-phase meter support.
- Optimisation: Battery data error checking improvements.
Version A318-D318 | 26-08-2025
- Fix: Correct load reading when external PV metering is disabled but still connected for third-party use.
- Fix: BMS current value now observes correct signed integer notation.
Version A317-D317 | 07-08-2025
- New feature: Add BMS AI self-heating logic. Enable/disable in inverter controls (requires BMS 3022+ or 4009+).
- New feature: External generation meters include/exclude option for inverter totals (default: include).
- Bug fix: Clear hung battery data registers if BMS communication is lost.
Version A316-D316 | 05-04-2025
- Add wider import limit for EU (1–255 A).
- Optimise PV energy when using external PV systems.
- Fix leap year bug.
- Optimise off-grid voltage and frequency display during overload conditions.
- Fix charge target SOC bug where the target was sometimes ignored.
Version A315-D315 | 09-02-2025
- Correct reserve and cutoff register mapping.
Version A314-D314 | 27-12-2024
Beta users only
- Add additional registers for Grid Services.
- Optimise no-battery operation behaviour.
- Optimise front inverter display.
Version A313-D313 | 09-12-2024
Internal
- Add BMS 3018 support. Mini calibration performed on full charge if required.
- Add real-time registers allowing “Safe Registers” to be held in RAM. When transitioning to EEPROM, a 2-second delay applies before writing.
- Import limitation default remains 100 A and disabled. Allowable range changed to 40–200 A.
Version A312-D312 | 01-10-2024
Internal
- Add BMS 3018 support.
Version A311-D311 | 23-08-2024
Internal & beta users
- Fix off-grid discharge cutoff.
- Add import limitation (0–200 A configurable).
- Fix relay issue under rare grid conditions causing incorrect EPS operation.
- Add BMS reset command.
Version A309-D309 | 16-05-2024
- Add additional PV total registers for external PV included in internal PV totals (portal update required).
- Add inverter mode register (Hybrid/String) to suppress intended “battery not present” warnings.
- Optimise firmware file removal after update.
- Add Australian Grid Codes A, B, C and New Zealand Grid Code parameters.
- Add Australian DRM function and optimise communication with Australian DRM dongle firmware 9xx.
Version A308-D308 | 09-02-2024
- Optimise SOC calibration behaviour near 5%.
- Fix export limit overflow error.
- Optimise battery removal mechanism when sleep function is used.
- Fix Off-Grid mode error.
- Add EN50549 certifications.
- Optimise PV MPPT logic.
- Add quick protection function for battery overvoltage interruption.
- Add EMS CPU parallel control parameters.
- Fix 10-stage charge/discharge crossing midnight bug.
Version D307-A307 | 13-10-2023
- Optimise ageing test behaviour.
- Change initial GEN3 battery undervoltage protection from 45 V to 43.2 V.
Version D306-A306 | 29-09-2023
- Optimise export and import EnergyToday zeroing at midnight.
- Optimise inverter status display during charging.
- Optimise 418 meter information query.
- Reduce MPPT minimum voltage from 130 V to 120 V.
- Optimise SOC handling after PCS–BMS communication loss beyond 30 seconds.
- Fine-tune off-grid control parameters.
- Increase PV high-voltage limit from 300 W to 3600 W.
- Modify grid-to-off-grid relay cutoff delay.
- Remove automatic lithium/lead-acid identification to reduce overcharge and comms risk.
Version D305-A305 | 07-07-2023
- Add 0-second switching (UPS) function.
Version D304-A304 | 20-06-2023
- Add G98 NI and G99 NI certifications.
- Optimise inverter overcurrent behaviour when battery disconnects.
- Optimise CRC handling in 0x10 multi-set function.
- Optimise SOC clearing logic on battery fault disconnect.
- Optimise current compensation loop.
Version D303-A303 | 19-05-2023
- Add 0x10 multi-register setting function.
- Optimise AC charge logic allowing discharge when SOC is greater than set point.
- Fix solar export issues when battery is full.
- Increase single PV string power limit to 1.5 TPn.
Version D302-A302 | 03-04-2023
- Add ageing mode allowing two inverters to operate together.
- Add EN50549 security certification.
- Add charging and discharging power calibration coefficients.
- Optimise refresh rate of detailed battery information.
- Optimise AC charge-to-percentage mode settings.
- Optimise grid power readings.
- Optimise PV power readings.
- Lower MPPT start voltage to 130 V.
- Increase Buck-Boost overtemperature protection and load reduction threshold by 5°.