Version BABA0009 | 08-08-2025
- Optimise OCV table for improved multi-stack balance charging.
Version BABA0008 | 01-06-2025
Internal release only – testing mismatched HV box old and new styles together.
Version BABA0007 | 24-03-2025
Public release
- Added parallel machine calibration function.
- Added full charge capacity fix.
- Added temperature-based loading and unloading function.
- Resolved parallel stacks SOC issues.
- Optimised single-cluster SOC strategy.
- Added differential pressure balancing strategy.
- Resolved the issue preventing remote upgrades when faults are present.
Version BABA0006 | 30-10-2024
- Fix abnormal temperature readings.
Version BABA0005 | 09-10-2024
Not issued
- Add active balancing tasks.
- Fix overvoltage alarms sent to the server.
- Add version number reporting for derivative software.
- Add fault event reporting functionality.
- Fix incorrect production parameters.
- Increase loop anomaly protection.
- Support 64 GB USB drive upgrades.
- Buzzer sounding optimisation.
- Disable temperature rise protection and add fast temperature protection.
- Optimise SOC estimation.
- Resolve overcurrent issues in parallel hardware.
Version BABA0004 | 20-06-2024
- Fix error when briefly carrying a 17 kW load.
- Resolve SOC not updating when charging from PV.
- Change static OCV condition threshold from 1 A to 2 A.
- Add static consumption tracking.
- Change hardware overcurrent error to a recoverable protection.
- Add parallel and single detection to resolve total voltage detection issues.
- Remove SOC saving under HV box parallel conditions.
- Fix insufficient battery capacity issue during manufacturing.
Version BABA0003 | Date not specified
- Transplant latest BMS strategy from BAAA0009.
- Add parallel automatic addressing function.
- Add one-key on/off function for parallel machines.
- Add automatic/static closing function.
- Add parallel fault diagnosis function.
- Add parallel SOP.
- Add parallel SOC.
- Add parallel upgrade function.
- Add parallel communication function.
- Add parallel black start function.
- Add parallel mode conversion function.
- Add LED display function.
Version BABA0002 | Date not specified
- Add CAN messaging with PCS.
- Handle SOC jump issues.
- Remove restriction where current collection above 0.2 A was forced to zero.
- Modify charge and discharge over-temperature and under-temperature thresholds.
- First version released.