Stackable HV BMS Firmware Log
Version BABA0009 | 08-08-2025
- Optimise OCV table for improved multi-stack balance charging.
Version BABA0008 | 01-06-2025
Internal release only – testing mismatched HV box old and new styles together.
Version BABA0007 | 24-03-2025
Public release
- Added parallel machine calibration function.
- Added full charge capacity fix.
- Added temperature-based loading and unloading function.
- Resolved parallel stacks SOC issues.
- Optimised single-cluster SOC strategy.
- Added differential pressure balancing strategy.
- Resolved the issue preventing remote upgrades when faults are present.
Version BABA0006 | 30-10-2024
- Fix abnormal temperature readings.
Version BABA0005 | 09-10-2024
Not issued
- Add active balancing tasks.
- Fix overvoltage alarms sent to the server.
- Add version number reporting for derivative software.
- Add fault event reporting functionality.
- Fix incorrect production parameters.
- Increase loop anomaly protection.
- Support 64 GB USB drive upgrades.
- Buzzer sounding optimisation.
- Disable temperature rise protection and add fast temperature protection.
- Optimise SOC estimation.
- Resolve overcurrent issues in parallel hardware.
Version BABA0004 | 20-06-2024
- Fix error when briefly carrying a 17 kW load.
- Resolve SOC not updating when charging from PV.
- Change static OCV condition threshold from 1 A to 2 A.
- Add static consumption tracking.
- Change hardware overcurrent error to a recoverable protection.
- Add parallel and single detection to resolve total voltage detection issues.
- Remove SOC saving under HV box parallel conditions.
- Fix insufficient battery capacity issue during manufacturing.
Version BABA0003 | Date not specified
- Transplant latest BMS strategy from BAAA0009.
- Add parallel automatic addressing function.
- Add one-key on/off function for parallel machines.
- Add automatic/static closing function.
- Add parallel fault diagnosis function.
- Add parallel SOP.
- Add parallel SOC.
- Add parallel upgrade function.
- Add parallel communication function.
- Add parallel black start function.
- Add parallel mode conversion function.
- Add LED display function.
Version BABA0002 | Date not specified
- Add CAN messaging with PCS.
- Handle SOC jump issues.
- Remove restriction where current collection above 0.2 A was forced to zero.
- Modify charge and discharge over-temperature and under-temperature thresholds.
- First version released.
Related Articles
BMS Gen 3 Firmware Log
Version BMS3-4011 | 18-12-2025 Internal resistance check optimisation. External protocol optimisations. Multiple battery pre-charge optimisation. Initial power-on SOC issues resolved. Cell over-voltage alarms adjusted to reduce false triggering. ...
BMS Gen 1 & 2 Firmware Log
Version 3022 — BMS 2.0 | 13-06-2025 Optimise issue where SOC does not drop from 100% after a minor overvoltage alarm. Optimise balance activation conditions: passive balancing is disabled when a battery cell detection fault is present. Version 3021 — ...
Stackable Batteries Manual
Download Manual This article summarises the Stackable Batteries Manual, which applies to the GivEnergy Stackable Battery System. This system consists of a base module with integrated electronics and stackable battery modules that can be added to ...
High Voltage Stackable Batteries Datasheet
Download Datasheet The GivEnergy High Voltage Stackable Battery range provides modular commercial-grade energy storage in 10.2 kWh, 13.6 kWh, 17.0 kWh and 20.4 kWh configurations. Designed for high-voltage inverter systems, these batteries use ...
3-Phase Parallel Firmware Log
Version ZB040404 | 26-12-2025 Certification update: DRM3 and DRM7 updated for AU to output reactive power. Fix: Optimise LoRa communications. Fix: Correct meter data power factor value. Fix: In parallel systems, load value previously reflected whole ...