G3-HV Firmware Log

G3-HV Firmware Log

Version SG050505 | 18-04-2025

  1. Set import limit to the maximum available range of 1–255 A.
  2. Optimise reserve/cut-off register usage, improving transition from Off-Grid back to On-Grid.
  3. Add external PV calculations to internal PV energy generation values.
  4. Optimise energy calculation when using a CT.
  5. Other internal minor improvements.

Version SG040404 | 02-03-2025

  1. Add external metering support (direct read for Grid Services) using function codes 0x04 and 0x16 for ID01–08.
  2. Alter import limit range to 1–200 A (previously 40–200 A).

Version SG030303 | 17-01-2025

  1. Support multiple battery stacks with parallel battery functions.
  2. Export limit optimisation.
  3. Internal logic optimisation.
  4. Add battery force wake (activate) function via PV or AC.
  5. Reserve and cut-off optimisations.

Version SG020202 | 12-12-2024

  1. Various design optimisations for off-grid performance.
  2. AFCI logic optimisation.
  3. Add off-grid power readings.
  4. Energy display optimisation.
  5. Add SafeRegister function for Grid Services.
  6. Add import limitation function; default 100 A and disabled.

Version SG010101 | 01-12-2024

  1. Initial release version for testing and factory use only.
    • Related Articles

    • Stackable HV BMS Firmware Log

      Version BABA0009 | 08-08-2025 Optimise OCV table for improved multi-stack balance charging. Version BABA0008 | 01-06-2025 Internal release only – testing mismatched HV box old and new styles together. Version BABA0007 | 24-03-2025 Public release ...
    • 3-Phase Parallel Firmware Log

      Version ZB040404 | 26-12-2025 Certification update: DRM3 and DRM7 updated for AU to output reactive power. Fix: Optimise LoRa communications. Fix: Correct meter data power factor value. Fix: In parallel systems, load value previously reflected whole ...
    • All-in-One (AIO) Firmware Log

      Version A620-D620 | 27-09-2025 Bug fix. Add missing hardware type codes for the 3.6 kW and 5 kW versions of AIO. Version A619-D619 | 19-08-2025 Bug fix. Multiple grid loss EPS fix. Version A618-D618 | 29-04-2025 BMS upgrade optimisations. Add new ...
    • Gateway Firmware Log

      Version Gateway GAAA0014 | 02-11-2025 Optimise LED display. Version Gateway GAAA0013 | 29-04-2025 Optimise G99 standard for relay reconnection to grid. 3-phase metering over-current reporting fix. Version Gateway GAAA0012 | 07-04-2025 Add import ...
    • 3-Phase Single Firmware Log

      Version ZAAA111111 | 14-11-2025 Optimize meter communications when using LoRa. Correct meter power factor data reading via protocol. Optimise Active Power vs Frequency operation. Revise DRM function for updated Australian standards. Increase battery ...

    GivBot