All-in-One BMU Firmware Log
Version BAAA0013 | 03-05-2025
- OCV SOC improvements during charging and discharging.
- Ultra-low battery activation below 80 V (Service Desk use only). Requires inverter version 618 or higher.
- BCU can be remotely updated even while in a fault state.
Version BAAA0012 | 17-02-2025
- Add full charge capacity function.
- Add voltage difference balance strategy.
- Optimise SOC strategy.
Version BAAA0011 | 12-12-2024
Test release
- Add event query function so the inverter can query BMS events.
- Optimise fault self-diagnostics.
- Optimise over-voltage alarm logic.
- Optimise SOC calculation (requires inverter D614-A614).
- Support large USB drive capacity (>8 GB). Future upgrades no longer require small USB drives.
Version BAAA0010 | 17-06-2024
No calibration required from BMS9.
- Resolve issue where SOC did not adjust when charging from PV.
- Static OCV optimisation to improve SOC self-calibration.
Version BAAA0009 | 15-03-2024
- BMU hibernate wait time extended from 10 to 30 minutes.
- Optimise logic for RTC clock failure error.
- Optimise passive cell balance logic.
- Improve self-calibration logic for lower temperatures and currents (now requires 10 °C and 6 A charge).
- Improve SOC calculation to enhance SOC tracking and capacity accuracy.
- Allow wake and activation from grid if hibernated due to low voltage.
Version BAAA0008 | 07-12-2023
- Compatibility with CCS battery modules.
- Modify SOC estimation logic (new OCV logic).
- Incorporate battery activation and remote wake-up.
- Fix stuck BCU and lock-up issues.
- Change balanced duty cycle to 50% for passive cell equalisation.
Version BAAA0007 | 19-09-2023
- Add CAN packets to PCS.
- Improve SOC tracking to reduce likelihood of SOC error.
- Release 0-limit current collection above 0.2 A.
- Change charge and discharge over-temperature and under-temperature thresholds.
Version BAAA0006 | 10-06-2023
- Handle voltage difference and temperature difference alarm issues.
- Fix current sampling anomalies.
- Add temperature collection routine.
- Fix incorrect cell temperature readings.
- Fix insulation protection alarm failure.
- Allow more than 1000 mV to be added during charging.
- Add fast charge and discharge functions.
- Add equalisation count clearing function.
- Fix SOC reading inaccuracies.
- Fix OCV table checking failure.
Version BAAA0005 | 10-05-2023
- Add fault masking function.
- Change current collection fault to non-auto-recoverable.
- Fix failure to enable 13S balancing.
Version BAAA0004 | 17-04-2023
- Add upload and configuration of adjustment parameters.
- Add OCV enablement function.
- Add balancing time calculation function.
- Add reset function.
- Add restore default protection threshold function.
- Add 1 Ah to 1% SOC correspondence function.
- Optimise BMU dynamic data update behaviour.
- Add off-grid upgrade function.
- Fix serial number high/low bit exchange.
Related Articles
All-in-One (AIO) Firmware Log
Version A620-D620 | 27-09-2025 Bug fix. Add missing hardware type codes for the 3.6 kW and 5 kW versions of AIO. Version A619-D619 | 19-08-2025 Bug fix. Multiple grid loss EPS fix. Version A618-D618 | 29-04-2025 BMS upgrade optimisations. Add new ...
Gen 2 Hybrid Firmware Log
Version A922-D922 | 02-09-2025 New feature: Add BMS AI logic self-heating functions. Enable/disable in inverter controls (requires BMS 3022+ or 4009+). Fix: BMS current value now observes correct signed integer notation. Fix: Clear hung battery data ...
All-in-One 2 (AIO2) Firmware Log
Version SI030606 | 28-11-2025 (MPPT 03, Inverter ARM/DSP 06) Fix: PV Today reset. Version SI030505 | 10-11-2025 (MPPT 03, Inverter ARM/DSP 05) Optimise master/slave battery checks; if a mismatch is detected, an upgrade is triggered. UPS Mode enabled ...
All in One & Giv-Gateway Manual
Download Manual This manual contains the installation, configuration, and safety information from the GivEnergy All in One & Giv-Gateway User Manual for models GIV-AIO-13.5, GIV-AIO-13.5-3.6 and GIV-AIO-GW1. It is intended as a quick reference for ...
Gateway Firmware Log
Version Gateway GAAA0014 | 02-11-2025 Optimise LED display. Version Gateway GAAA0013 | 29-04-2025 Optimise G99 standard for relay reconnection to grid. 3-phase metering over-current reporting fix. Version Gateway GAAA0012 | 07-04-2025 Add import ...