Version A214-A214 | 02-11-2025
- Fix grid/inverter balance issue with tighter control of the net-zero balance point.
Version A213-D213 | 27-08-2025 (Not Released)
- Add new register for controlling BMS AI heating logic.
- Optimise BMS no-communication recovery.
- Fix BMS current register when values are negative (Engineer Data).
Version A212-D212 | 05-03-2025 (Public Release)
- Modify import limit for EU customers to a range of 1–255 A.
- Fix bug where target SOC was ignored for some users.
- Optimise Blue CT PV power and energy calculations.
- Optimise load energy calculation.
Version A211-D211 | 02-03-2025 (Test Only)
- Add direct read support for 8 meters (Grid Services use).
- Fix PV parasitic load displaying as generation on Blue CT. Blue CT is now directional (Positive / Negative / Auto, default Auto).
Version A210-D210 | 09-02-2025 (Public Release Mar 2025)
- Correct reserve and cut-off register mapping.
Version A209-D209 | 27-12-2024 (Internal & Beta Tester Release)
- Add additional SafeMode registers for Grid Services.
- Optimise inverter front display for battery.
Version A208-D208 | 09-12-2024 (Not Published Externally)
- Add BMS 3018 support with mini calibration on each full charge if required.
- Add real-time registers allowing Safe Registers to be held only in RAM. When transitioning from RAM to EEPROM mode, a 2-second delay is applied and Safe Registers are written to EEPROM.
- Set import limitation default to 100 A (disabled). Allowable range: 40–200 A.
Version A207-D207 | 23-08-2024 (Internal Use)
- Fix sporadic EPS relay issue under certain rare grid conditions.
- Send meter information (meter serial number) to the portal.
- Add G100/2 import limitation function.
- Add restart battery function.
Version A205-D205 | 22-05-2024
- Optimise meter setting logic for mixed metering using new binary mapping addresses.
- Optimise remote upgrade logic.
Version A204-D204 | 09-02-2024
- Fix export limit overflow error.
- Optimise battery removal mechanism when receiving battery sleep instruction.
- Add additional EN50549 certifications.
- Add quick protection function for battery overvoltage interruption.
- Add EMS CPU parallel control parameters.
Version D203-A203 | 05-12-2023
- Add new holding registers 498–508 for inverter fail message and BUG voltage.
- Remove automatic identification of lithium and lead-acid batteries.
- Add logic forcing discharge in AC-coupled mode when BMS is overcharging.
- Optimise Off-Grid relay operation.
Version D202-A202 | 22-08-2023
- Optimise AC charge-to-percentage behaviour to reduce oscillations.
- Add and refine multiple EU grid certifications.
- Correct negative temperature sampling issue (-0.1°C reading as 65535°C).
Version D201-A201 | 18-08-2023
- Fully rewrite AC-coupled firmware with optimised code and faster response times, matching feature set of D535–A535.
- Add Battery Pause register allowing DC pause of battery charge, discharge, or both.
- Add G100 on/off flag for export limitation control.