3-Phase Parallel Firmware Log

3-Phase Parallel Firmware Log

Version ZB040404 | 26-12-2025

  1. Certification update: DRM3 and DRM7 updated for AU to output reactive power.
  2. Fix: Optimise LoRa communications.
  3. Fix: Correct meter data power factor value.
  4. Fix: In parallel systems, load value previously reflected whole system instead of per inverter.
  5. Fix: EPS logic optimisation when switching from Island Mode to On-Grid.
  6. Fix: Optimise BMS error log data handling while in Off-Grid mode.
  7. New feature: Add support for generator control.

Version ZB030303 | 16-06-2025

  1. Optimise ECO mode to balance SOC during parallel operation.
  2. Resolve parallel BMS upgrade issue.
  3. Add backward compatibility for older SDM630 meters using FC 0x16.
  4. Optimise operation with inductive (high inrush) loads while in Island Mode.
  5. Add meter wiring detection function (see document: GIV-3HY-6~20K-HV Meter Wiring Detection Function SOP V1.0).

Version ZB020202 | 18-04-2025

  1. Optimise inverter power derating logic under high-temperature conditions.
  2. Start-up optimisation when both battery and PV are present: system boots on battery first, then engages PV.
  3. Update overload logic: three overloads in 5 seconds or five in 1 minute triggers fault; inverter waits 1 minute and self-recovers. Three faults within 1 hour disables self-recovery and raises “OCP Times Excessive”.
  4. Optimise fan self-test logic.
  5. Include externally monitored PV (ID2 & ID3) in total PV energy calculations.
  6. Parallel function optimisations.
  7. Optimise AFCI sensitivity.
  8. Improve parallel battery cluster calibration logic (requires BABA0007 or higher).
  9. Add RTCL “Safe Registers” for Grid Service functions to reduce excessive flash memory writes.
  10. Set default current limit to 100 A (disabled by default) with configurable range from 1–2000 A for commercial installations.
  11. Add Czech grid standards.

Version ZB010101 | 01-02-2025

  1. Initial factory release.
    • Related Articles

    • 3-Phase Single Firmware Log

      Version ZAAA111111 | 14-11-2025 Optimize meter communications when using LoRa. Correct meter power factor data reading via protocol. Optimise Active Power vs Frequency operation. Revise DRM function for updated Australian standards. Increase battery ...
    • Gateway Firmware Log

      Version Gateway GAAA0014 | 02-11-2025 Optimise LED display. Version Gateway GAAA0013 | 29-04-2025 Optimise G99 standard for relay reconnection to grid. 3-phase metering over-current reporting fix. Version Gateway GAAA0012 | 07-04-2025 Add import ...
    • Gen 3 Hybrid Firmware Log

      Version A319-D319 | 22-12-2025 New feature: Add 3-phase meter support. Optimisation: Battery data error checking improvements. Version A318-D318 | 26-08-2025 Fix: Correct load reading when external PV metering is disabled but still connected for ...
    • All-in-One (AIO) Firmware Log

      Version A620-D620 | 27-09-2025 Bug fix. Add missing hardware type codes for the 3.6 kW and 5 kW versions of AIO. Version A619-D619 | 19-08-2025 Bug fix. Multiple grid loss EPS fix. Version A618-D618 | 29-04-2025 BMS upgrade optimisations. Add new ...
    • BMS Gen 3 Firmware Log

      Version BMS3-4011 | 18-12-2025 Internal resistance check optimisation. External protocol optimisations. Multiple battery pre-charge optimisation. Initial power-on SOC issues resolved. Cell over-voltage alarms adjusted to reduce false triggering. ...

    GivBot